6ton precision air conditioning
| Model No. | JHF24 | |||
| Unit performance | Cooling capacity | kW | 21 | |
| Electric heating capacity | kW | 9 | ||
| Cooling consumed power | kW | 17 | ||
| Air flow | m3/h | 6000 | ||
| External static pressure | Pa | 100 | ||
| Power supply | 3N~380V,50Hz | |||
| Refrigerant | R410a | |||
| Indoor unit | Fan | Fan way | upper or down | |
| Motor power | kW | 1.5 | ||
| Humidification | Humidifying | Kg/h | 4 | |
| Power | kW | 3 | ||
| Outdoor unit | Model No. | SW08 | ||
| Compressor | Type | Hermetic scroll compressor | ||
| Condenser type | Copper tube with aluminum fins | |||
| Motor power | kW | 0.75 | ||
| Power supply | 3N~380V,50Hz | |||
| Connection tube | Gas tube(mm) | Φ12.7 | ||
| Quantity | 2 | |||
| Liquid tube(mm) | Φ9.52 | |||
| Quantity | 2 |











Executive Summary
Today's technology rooms require precise, stable environments in order for sensitive electronics to
operate optimally. Standard comfort air conditioning is ill suited for technology rooms, leading to system
shutdowns and component failures. Because precision air conditioning maintains temperature and
humidity within a very narrow range, it provides the environmental stability required by sensitive
electronic equipment, allowing your business to avoid expensive downtime.
Defining Today’s Technology Rooms -
Not Just Computer Rooms Anymore
Precision environmental control requirements now reach far beyond the confines of the traditional data center or
computer room to encompass a larger suite of applications, referred to as “Technology Rooms”.
Typical technology room applications include:
1- Medical equipment suites (MRI, CAT scan)
2- Clean rooms
3- Laboratories
4- Printer/copier/CAD centers
5- Server Rooms
6- Hospital facilities (operating, isolation rooms)
7- Telecommunications (switch gear rooms, cell sites)
One of the highest growth application areas is telecommunications, including a wide range of facilities from
simple remote switch stations to complex central exchange centers.
Why Do I Need Precision Air Conditioning?
Because information processing is the lifeblood of all critical operations, reliability in your technology room is vital to your company's health. IT hardware produces an unusual, concentrated heat load, and at the same time, is very sensitive to changes in temperature or humidity. A temperature and/or humidity swing can produce problems ranging from processed “gibberish” to a complete system shutdown. This can create huge costs for the company, depending on the length of the interruption and the value of time and data lost. Standard comfort air conditioning is not designed to handle the heat load concentration and heat load profile of technology rooms, nor is it designed to provide the precise temperature and humidity set point required for these applications. Precision air systems are designed for close temperature and humidity control. They provide high reliability for year-round operation, with the ease of service, system flexibility and redundancy necessary to keep the technology room up and running 24 hours a day.
Hot Tags: 6ton precision air conitioner, China, manufacturers, customized, quotation, low price, made in China, Computer Room Precision AC, Computer Room Air Conditioner CRAC , 100KW Laboratory Precision Air Conditioner, Datacenter Precision Air Conditioner, Multi functional Precision Air Conditioner, 15kw Precision Air Conditioner