Main factors should be considered when selecting the equipment model:
1. Heat of devices in the equipment room
2. Equipment room area
3. Computer Room Network Management Precision AC (including layer height, sealing, decoration, outdoor unit installation position, etc.)
4. Local weather conditions
5. The model and specifications are rounded and identical
6. Computer Room Network Management Precision AC should be able to automatically adjust the indoor temperature, humidity, according to the requirement with cooling, heating, humidification, dehumidification, and other functions.
7. Computer Room Network Management Precision AC should be modular models to choose from, each module should have refrigeration, heating, humidification, dehumidification and temperature, humidity sensor and controller. Each module can be run at the same time also can work independently.
7. Refrigeration performance: the evaporator area as large as possible, can rapid cooling dehumidification, ensure energy saving.
Technical specification:
Room precision air conditioner | ||||
Model No. | JH/JHF | |||
Unit Performance | Cooling Type | Water-cooled/Air-cooled | ||
Cooling capacity | kW | 6.71~146 | ||
Electric heating capacity | kW | 4.5~56 | ||
Cooling consumed power | kW | 2.7~50.3 | ||
Air flow | m3/h | 2200~34000 | ||
External static pressure | Pa | 30~80 | ||
Power supply | 220/380/460V-3N-50/60Hz | |||
Refrigerant | R22/R407c/R410a | |||
Indoor unit | Fan | Fan way | Upper/Front/Down supply | |
Motor power | kW | 0.18~11 | ||
Humidification | Humidifying | Kg/h | 4~25 | |
Power | kW | 3.7~18.75 | ||
Noise level | dB(A) | ≤53~72 | ||
Model No. | SW | |||
Outdoor unit | Compressor | Type | Rotor/Scroll | |
Power | kW | 2.25~36 | ||
Condenser type | Copper tube aluminum fins | |||
Blower power | kW | 0.37~4.4 | ||
Noise level | dB(A) | <62~69 | ||
Connection tube | Gas tube(mm) | Φ12.7/Φ15.9/Φ19.1 | ||
Quantity | 1~5 | |||
Liquid tube(mm) | Φ9.52/Φ12.7 | |||
Quantity | 1~5 | |||
Connection | Flare opening | |||
Note: | ||||
1. Return air vent are equipped with G4 air filter. | ||||
2. Control temperature range between 18-32℃,accuracy of ±0.5℃ | ||||
3. Humidity control range of 40~80%, with an accuracy of ± 3% | ||||
4. Compressors are put indoor units. | ||||






FAQ:
Q1:How about the price of this product?
A1:This product can be different capacity and quantities, so you can contact me directly to know the accurate price.
Q2:I want to known more information, how can I contact with you?
A2:I am Angie Pan. You can directly contact me see above namecard.
Q3: How about the quality of your product?
A3: Our products strictly manufatured according to national and international standard. We got ISO quality and CE,CCS,SGS…etc.
Q4:How about the price of this product?
A4:This product can be different capacity and quantities, so you can contact me directly to know the accurate price.
Hot Tags: Computer Room Network Management Precision AC, China, manufacturers, customized, quotation, low price, made in China, DC Inverter Precision AC, Museum Precision Air Conditioner, 20 Kw Precision Air Conditioner, 100KW Laboratory Precision Air Conditioner, ComputerRoom Precision Air Conditioner, 100KW UPS Precision Air Conditioner