Chilled Water Type Precision Air Conditioning System

Chilled Water Type Precision Air Conditioning System

The following introduces several traditional and new cooling methods for data centers. 1. Composition of chilled water type precision air conditioning system The structure of the chilled water type precision air conditioning unit is simple, and the composition is shown in the figure below. The unit is mainly composed of frame, chilled water coil, indoor EC fan, electromagnetic two-way regulating valve (electric ball valve), control system, inlet and outlet air temperature and humidity sensor, chilled water pipeline, etc. 15 ° C low-temperature chilled water passes the precision air-conditioning chilled water coil to cool the 30 ° C return air in the machine room to 18 ° C. The cold wind cools the IT equipment in the machine room; 15 ° C low-temperature chilled water is heated to 21 ° C high temperature by the hot air in the machine room frozen water. The general setting is: the outlet temperature controls the opening of the two-way valve of the precision air conditioner, and the return air temperature controls the rotation speed of the EC fan. The chilled water type precision air conditioning unit needs to provide low temperature chilled water for external cooling (currently, the temperature of the water supply in large data centers is around 15 yuan). The chilled water type precision air conditioning system is generally composed of chilled water type precision air conditioning, chiller, cooling tower, freezing, cooling, piping and accessories. The Chiller type heat exchanger for chillers provides low-temperature chilled water for precision air conditioning.
Send Inquiry
Chat Now

Chilled water type precision air conditioning system

The HEAD-POWER Cool Energy Air Conditioning team is able to assess your exact requirement by carrying out a quick survey of your facility. 


The following introduces several traditional and new cooling methods for data centers.

1. Composition of chilled water type precision air conditioning system

The structure of the chilled water type precision air conditioning unit is simple, and the composition is shown in the figure below. The unit is mainly composed of frame, chilled water coil, indoor EC fan, electromagnetic two-way regulating valve (electric ball valve), control system, inlet and outlet air temperature and humidity sensor, chilled water pipeline, etc.

15 ° C low-temperature chilled water passes the precision air-conditioning chilled water coil to cool the 30 ° C return air in the machine room to 18 ° C. The cold wind cools the IT equipment in the machine room; 15 ° C low-temperature chilled water is heated to 21 ° C high temperature by the hot air in the machine room frozen water. The general setting is: the outlet temperature controls the opening of the two-way valve of the precision air conditioner, and the return air temperature controls the rotation speed of the EC fan.

The chilled water type precision air conditioning unit needs to provide low temperature chilled water for external cooling (currently, the temperature of the water supply in large data centers is around 15 yuan). The chilled water type precision air conditioning system is generally composed of chilled water type precision air conditioning, chiller, cooling tower, freezing, cooling, piping and accessories. The Chiller K® type heat exchanger for chillers provides low-temperature chilled water for precision air conditioning.

Room precision air conditioner features :



9.FAQ



Cindy Li 名片




Hot Tags: chilled water type precision air conditioning system, China, manufacturers, customized, quotation, low price, made in China, Air Cooled Precision Air Conditioner, 15ton Precision Air Conditioning Unit, HVAC System Precision Air Conditioner Unit, LAB Precision Air Conditioner 58KW 500KW, 20 Kw Precision Air Conditioner, Precision Central Air Conditioner Installation