the breif instroduction of 50kw Crac Precision Air Conditiner:
System Selection
Air Cooled • Refrigeration system can “split” between indoor air conditioner and outdoor aircooled heat rejection unit or packaged with both evaporator and condenser outside. • Compressors can be located in the indoor or outdoor equipment. • Field installed refrigerant pipelines (two per compressor or circuit) may interconnect indoor and outdoor units. Packaged units are provided with all refrigerant pipelines installed and tested. • For split systems, refrigerant piping design is critical. The design must address pressure losses, refrigerant velocities, oil return, and traps. • Excellent for multiple units and expanding installations. Packaged systems are selfcontained, stand-alone modules.
the specification of 50kw Crac Precision Air Conditiner:
| Model No. | JHF58 | |||
| Unit performance | Total Cooling capacity | kW | 58 | |
| Useful cooling capacity | kW | 52 | ||
| Electric heating capacity | kW | 18 | ||
| Cooling consumed power | kW | 31 | ||
| Air flow | m3/h | 15000 m3 / h | ||
| External static pressure | Pa | 150 | ||
| Fiter | G4 | |||
| Power supply | 300v,3phase,50hz | |||
| Refrigerant | R410a | |||
| Indoor unit | Fan | Fan way | upper or down | |
| 风机个数 | 2 | |||
| Motor power | kW | 5.5 | ||
| Humidification | Humidifying | Kg/h | 8 | |
| Power | kW | 6 | ||
| Dimension | mm | 1980 * 2100 * 890 mm | ||
| Outdoor unit | Model No. | SW20 | ||
| Compressor | Type | Hermetic scroll compressor | ||
| consumption power | kW | 14KW | ||
| Condenser type | Copper tube with aluminum fins | |||
| Fan Motor power | kW | 0.9*2 | ||
| Air flow | 25500 m3 / h | |||
| Maximum operating current | A | 6.5 | ||
| Power supply | 230/1/50 | |||
| Connection tube | Gas tube(mm) | Φ28 | ||
| Quantity | 2 | |||
| Liquid tube(mm) | Φ15.88 | |||
| Quantity | 2 | |||
| Dimension | mm | 2000*1100*1200 mm; |


the product details of 50kw Crac Precision Air Conditiner






50kw Crac Precision Air Conditiner maintenance and repair
Correct operation and daily maintenance and repair, only only can extend unit’s lifetime, but also can highly improve the efficiency and reduce energy consumption. It is suggested that it is operated, managed and maintained by professional technical workers. It also requires checking the unit periodically and judging whether the unit runs in normal condition. If something wrong happens, please handle in time, and record monthly, seasonal and annual maintenance data, which is convenient for further faults in the further.
1). ensure the ground-line wiring symbol and wiring column in the electric box are tightly connected with ground;
2). monthly check the power supply and con compressor’s phase voltage;
3). before start the unit, please confirm whether the compressor is switching with electric-heating or not;
4). if no emergency happens, don’t cut off the total power supply to stop the unit. When faults alarms, firstly press the stop button, then check the faults reason; before cleaning up the faults, don’t start the unit;
5). periodically check unit’s running status, check system’s high&low-pressure and oil level are normal or not. If something wrong happens, handle them in time;
6). periodically check the oil pressure difference of compressor oil, if it is larger than 0.3kgf/cm2, please discharge and clean them, at the same time, please clean some impurities under the oil pan; (only for seme-hermetic compressor)
Hot Tags: 50kw crac precision air conditiner, China, manufacturers, customized, quotation, low price, made in China, Precision Air Conditioner For Control Rooms, HVAC System Precision Air Conditioner Unit, Biochemical Laboratory Precision Air Conditioner, 75ton 380v R407c Precision Air Conditioner, Computer Room Air Conditioner, Precision Air Conditioner Spare Parts