Large Capacity Chilled Water Air Handling Unit Shipment

Nov 05, 2020 Leave a message

Guangdong Head-Power Air Conditioning Co.,Ltd. We specialized in refrigeration equipment (air-cooled/water-cooled packaged unit,rooftop packaged unit,chiller,dehumidifier,fresh air handling unt, heat pump,spilt type AC, closed control AC,AHU) for many years. With strength of quick reaction in non-standard AC and new refrigerant AC.


This series of products is the terminal equipment of the central air-conditioning system, which is widely used in air-conditioning projects in various industries such as hotels, buildings, theaters, airports, hospitals, industrial and mining enterprises, and scientific research units. Product series model : PWD350-6H,Cooling capacity 288.5KW,air flow 35000 m3/h , floorstanding or ceiling mounted duct type is accepted .Motor power 7.5KW,6 pole, galvanized steel outer painting , galvanized steel panel inside , with 30mm PU foam . Return air inlet use nylon mesh net . Power source 380V/3PH/50HZ or other special power source is customized . PWD350-6H unit size is 3900*1800*1380mm.


◎Frame structure

 The latest reinforced aluminum alloy profile is used, with surface being subject to anodic oxidation treatment and internal foamed, to prevent the sweat phenomenon on the frame surface, being firm and beautiful.

 ◎Panel structure

 Double-skin panel structure, with 25mm thickness foam insulation, galvanized steel sheet. With beautiful appearance, anti-corrosion, The panel has firm structure and excellent performance against sound and vibration.

 ◎Structure of heat exchange oil

 The heat exchange tubes are arranged in the triangular staggered manner, generally 4-8 rows; the heat exchanges tubes are made of high-quality copper (TP2).

The high-efficient heat exchanger is made on U.S. OAK assembly line. After overall passing through, the copper tube is closely integrated with the aluminum pieces, providing excellent heat transfer effect, satisfactory for the occasions of the thermal performance requirements; precision processing machinery and strict processing control ensure uniform piece distance and tight tube expansion.   The external frame of the coil is bent formed with galvanized steel sheet, being firm and durable; bolt connections are used to prevent rust due to welding of the galvanized layer.

The design work pressure of the coil is 16 bars, test pressure 25bars.

 ◎ Fans and motors

 Double air-intake centrifugal efficient fans , with international famous brands fan bearing, easy for repair and maintenance.Famous fan motors are used, with insulation class B so as to ensure the quality and service life; In addition, the motors of given brands can be provided when user requires so that motor insulation class can be enhanced in order to meet the needs of different occasions.The fans are belt-driven , i.e. high-quality V-shaped belts; belt pulleys are precisely machined to ensure concentricity and in accurate matching of the belt; after fans and motors assembly, the second running dynamic balance inspection is carried out in order to achieve the minimum vibration and the highest transmission efficiency.The bases of fans and motors are all equipped with suitable damper spring shock absorbers; fan outlets and outside box are all flexibly connected using anti-corrosive and moisture-resistant canvas.

 ◎  Coil design

 According to varied flows, temperature differences and operating conditions, different internal process designs are adopted in order to maintain coil heat exchange performance and coil water pressure drop at a reasonable and efficient levels and reduce application difficulty; designed head-on wind speed is 2.5m/s-2.8m/s, and special design requirements are also acceptable.

◎  Filters

 Double nylon embossed nets are used, easy for replacement and removal, can be cleaned and used repeatedly. Non-woven plate filter can also be fitted at the air intake when required, or a new fresh return air mixing box be used.

Large dust capacity: under the designed final resistance (double the initial resistance), the dust capacity per square meter is more than 100g.


Installation and maintenance precautions of chilled water air handling unit .

1. Please check whether the machine is damaged during installation? Choose a suitable place for installation and future maintenance.

2. The place where the unit is installed must be the floor, installation mat or foundation, the level of which is above 50-100mm and can bear the operating weight of the unit.

3. The unit should be placed in a computer room with a room temperature of 4.4-43.3°C, and there should be enough space around and above the unit for routine maintenance.

4. At one end of the unit, there should be a space for pipe extraction to clean the condenser tube bundle. Door openings or other suitable openings can also be used.

5. Choose a water pipe with a suitable pipe diameter, and connect the cooling system and cold water system when the unit is running at maximum power.

6. For common applications, the water flow speed through the evaporator and condenser is allowed to be between 1.0-3.6m/s.

7. The water flow rate should remain stable under any load conditions.

8. The design and installation of all chilled water and cooling water pipelines should be carried out according to conventional methods. The chilled water pump should be located on the inlet pipe of the unit to ensure the positive pressure and flow rate in the unit. When piping, damping pipes should be installed to ensure proper elasticity and prevent the water from the evaporator from being drained when the pump is stopped. The pipeline should have a firm support independent of the chiller to avoid stress on the components of the chiller. The hanger should be set up to facilitate pipe alignment.

9. In order to reduce noise and vibration, it is best to install vibration isolators on the pipeline.

10. In order to use the chiller economically and effectively, it is recommended to ask a water treatment expert to analyze the water quality of the evaporator and condenser. Poor water quality will cause fouling, affect heat transfer or produce corrosion deposits, breed organic matter, and affect the performance of the unit, increase operation and maintenance costs .

11. Generally speaking, proper water treatment and regular cleaning of the tube bundle can maintain its good performance. If the existing water quality conditions cannot be improved by appropriate methods, then it is necessary to consider allowing the tube bundle to have a larger fouling coefficient or designating special structural materials.

12. Please install a filter at the entrance of the water pipe and clean it regularly.

13. After the leak test is completed, all the nozzles must be treated with rust prevention.