Here introduce DX Heat Recovery fresh air conditioning advantages :
1) Diversified functions, can be combined in any section according to needs; novel and beautiful structure, easy installation and convenient maintenance
2) High quality, reliable operation
◆ Refrigeration components, control components, motor fans and other operating components are all well-known brands with reliable quality;
◆ Adopt intelligent control, man-machine interface and standard communication protocol, stable control and high precision;
◆ Complete protection devices, stable and reliable operation.
3) DX Heat Recovery fresh air conditioning standard is galvanized steel plate sprayed on the outside and galvanized steel plate on the inner plate. The thermal insulation material is polyurethane foam thermal insulation material. You can choose to have rich experience in anti-corrosion and anti-rust design and long service life
Proudct Introduction
Heat Recovery Fresh Air Handling Unit
| Model Number | HAX015 | HAX025 | HAX030 | HAX040 | HAX050 | HAX060 | HAX070 | HAX080 | HAX100 | ||
| Cooling Capacity | KW | 9 | 12 | 16 | 19 | 23 | 28 | 33 | 36 | 46 | |
| Heating Capacity | KW | 9.5 | 12.6 | 16.7 | 20 | 24.3 | 30 | 35 | 39 | 49 | |
| Voltage | 220V~50HZ | 380V/3PH~50HZ | |||||||||
| Refrigerant | R22/R407C/R410A/R134A | ||||||||||
| Fresh Air System | Air Flow | m³/h | 1500 | 2500 | 3000 | 4000 | 5000 | 6000 | 7000 | 8000 | 10000 |
| External Static Pressure | Pa | 80 | 100 | 120 | 150 | 180 | 180 | 220 | 240 | 240 | |
| Motor Power | KW | 0.3 | 0.55 | 0.75 | 0.75 | 1.1 | 1.5 | 2.2 | 2.2 | 3 | |
| Discharge Air System | Air Flow | m³/h | 1500 | 2500 | 3000 | 4000 | 5000 | 6000 | 7000 | 8000 | 10000 |
| External Static Pressure | Pa | 80 | 100 | 120 | 150 | 180 | 220 | 240 | 250 | 280 | |
| Motor Power | KW | 0.3 | 0.55 | 0.75 | 0.75 | 1.1 | 1.5 | 2.2 | 2.2 | 3 | |
| Heat Exchange Efficiency | >87% | ||||||||||
| Compressor | Type | Rotor Type | Flexible Hermetic Scroll Compressor | ||||||||
| Power | KW | 1.7 | 2.25 | 2.5 | 3 | 3.75 | 4.5 | 3.75+2.2 | 3.75+2.2 | 3.75*2 | |
| Noise Level | dB(A) | 48 | 50 | 50 | 51 | 52 | 52 | 53 | 53 | 55 | |
Note:
1.Nominal cooling condition: indoor discharge air:DB27℃/WB19.5℃,outdoor fresh air: DB34℃/WB28℃.
2.Nominal heating condition: indoor discharge air:DB21℃/WB15℃,outdoor fresh air: DB7℃/WB6℃.
3. Ambient temperature conditions:-15℃~43℃
4. The specifications are subject to change without notice for improvement












Hot Tags: DX Heat Recovery fresh air conditioning, China, manufacturers, customized, quotation, low price, made in China, Wheel Heat Recovery Air Handling Unit, HRV Heat Recovery Ventilator, Heat Pump Heat Recovery Ventilator, 1500cmh Hrv Heat Recovery Ventilator, Residential Ventilator HRV, Heat Pump Fresh Air Handling Unit