Jet Nozzels Chilled Water Air Handling Unit
Jet Nozzels Chilled Water Air Handling Unit

Jet Nozzels Chilled Water Air Handling Unit

Jet Nozzels Chilled Water Air Handling Unit
Send Inquiry
Chat Now

Jet Nozzels Chilled Water Air Handling Unit(Chilled Water Coil) 5 Ton ~ 250 Ton HEAD-POWER CHINA

Make: HEAD-POWER CHINA

Nominal Cooling Capacity:  5 Ton ~ 250 Ton

Units are designed in accordance with ARI Standard for Coils (ARI 410) and ASHRAE Standard for Drain Pan (ASHRAE 62-89)

Double Wall 2” 40kg/m3 CFC-Free PU Insulation (HCFC 141b).

Isolates Insulation Exposure to the Air Stream.

Wide range of Coils offering – 4, 5, 6, 7, 8 Rows and 8, 10, 12, 14 FPI for Chilled Water. Optimized coil Circuiting.

All Chilled Water Coils are Factory Pressure Tested at 400 psig as Standard.

Coil tracks enable easy coil removal for complete cleaning and assurance of a dry unit interior.

Powder Painted Sloped Galvanized Steel Drain Pan with Bottom Drainage.

Forward Curved and Backward Curved (Airfoil Blade) Fan

- Forward Curved - Sizes 160 ~ 1000mm Diameter

- Backward Curved (Airfoil Blade) – Sizes 225 ~ 1000mm Diameter

Low leak construction with hex socket compression, type latch assemble and rib seals on mating panel perimeter.

The factory-installed unit base of 100mm height. 


                           Zk Series Round Jet Nozzels Assembly Air Handling Units



TypeZKZK
Items

1015
Air Flow  (m3/h) 1000015000
Section of Surface CoolingWindward Air Speed (m/s)2.5
Inlet/Outlet   Water Temperature ()7/12
Work   Pressure (Mpa)1.6
Return Air Condition Inlet Air Temperature (℃) DB27/WB19.5
4 RowsCooling Capacity (KW)58.188.0
Water Flow (T/h)10.015.1
Water Resistance (Kpa)4.85.6
Air Resistance (Pa)80
6 RowsCooling Capacity (KW)73.1106.6
Water Flow (T/h)12.618.3
Water Resistance (Kpa)6.87.6
Air Resistance (Pa)120
8 RowsCooling Capacity (KW)82.3122.8
Water Flow (T/h)14.121.1
Water Resistance (Kpa)9.010.2
Air Resistance (Pa)160
Fresh Air Condition Inlet Air Temperature (℃) DB34/WB28
4 RowsCooling Capacity (KW)113.5173.0
Water Flow (T/h)19.529.8
Water Resistance (Kpa)11.813.7
Air Resistance (Pa)90
6 RowsCooling Capacity (KW)123.1185.7
Water Flow (T/h)21.331.9
Water Resistance (Kpa)17.920.8
Air Resistance (Pa)130
8 RowsCooling Capacity (KW)142.8213.1
Water Flow (T/h)24.736.7
Water Resistance (Kpa)26.629.1
Air Resistance (Pa)170
Water   Connection  Pipe

Condensed   Water Pipe

Number   of Surface Cooler1
Section of HeatingInlet Air Condition ()DB15
Heated by Hot Water Inlet/Outlet Water Temp (℃) 60/50
2 RowsHeating Capacity (KW)69.8104.6
Water Flow (T/h)6.09.0
Water Resistance (Kpa)2.52.8
Air Resistance (Pa)55
4 RowsHeating Capacity (KW)87.2130.6
Water Flow (T/h)7.511.2
Water Resistance (Kpa)3.53.9
Air Resistance (Pa)80

Water Connection Pipe2"
Heated by Steam2 RowsHeating Capacity (KW)93.6140.4
Steam Pressure (Mpa)0.2
Steam Temperature ()115
Air Resistance (Pa)55
Water Connection Pipe2"
Heated by ElectricityElectric Power  (KW)1827
Heating   Capacity (KW)15.323.0
Power   of Every Group (KW)69
Temperature   Rise of Air  ()5.4
Air   Resistance (Pa)30
Section of HumidifyingHumidification   Capacity  (kg/h)3045
Dry   SteamPressure  (Mpa)0.1
Wet   FilmResistance  (Pa)2030
Section of Coarse FilterSpeed of Filtering m/s1.5
Efficiency   of Filtering5u   Counting Efficiency 90%G4
Original   Resistance / Eventual Resistance (Pa)50/100
Section of Medium Efficiency   FilterSpeed of Filtering  (m/s)0.3
Efficiency   of Filtering1u   Counting Efficiency 95%F8
Original   Resistance / Eventual Resistance (Pa)100/200
Sub-high Efficiency   / High Efficiency FilterInstalled According to the   Client's Reqirement


9.FAQ

Cindy Li 名片

Hot Tags: jet nozzels chilled water air handling unit, China, manufacturers, customized, quotation, low price, made in China, Operation Room Air Treatment Unit, ZK10 Chilled Water Air Handling Unit, Purifying Type Combined AHU, Spherical Spout Air Handling Unit, Chilled Water Air Handler, 25000 M3 h Air Treatment Unit