Ceiling ducted split air handling unit (DX type, indoor unit and outdoor unit make full set ) features of high-precision constant temperature and humidity unit:
1. Flexible design and tailor-made;
2. Stable operation and long service life;
3. Ultra-low noise and low energy consumption;
4. Ceiling ducted split air handling unit strong continuity, can work continuously without interruption throughout the year;
5. Ceiling ducted split air handling unit with high-precision temperature and humidity control system;
6. Humanized design: temperature and humidity can be adjusted automatically or manually;
| Split Ducted Type Air Conditioner | |||||||||
| Model | HADG08(H) | HADG10(H) | HADG12(H) | HADG15(H) | HADG18(H) | HADG20(H) | |||
| Indoor Unit Features | Cooling capacity | kw | 17.8 | 20.0 | 24 | 30.0 | 36 | 40.0 | |
| Heating capacity | kw | 19.1 | 21.5 | 26.0 | 32.5 | 39.2 | 44.8 | ||
| *Electric heating | kw | 6 | 8 | 9 | 12 | 15 | 16 | ||
| Air Volume | m3/h | 3600 | 4100 | 5500 | 6500 | 7600 | 8100 | ||
| External static pressure | Pa | 110 | 120 | 180 | 200 | 200 | 220 | ||
| Noise level | dB(A) | <52 | <56 | <60 | <65 | <65 | <67 | ||
| Power Supply | 380V/3N~50Hz | ||||||||
| Maximum Ambient Operating Temperature | 60℃ | ||||||||
| Refrigerant | Medium | R134a | |||||||
| Volume control | Expansion valve | ||||||||
| Evaporator | Type | Copper tubes with aluminium fins | |||||||
| Fin type | Two-way Slotted-type Aluminum Fin/Thermostatic Expansion Valve | ||||||||
| Fan | Type | Low-Noise Centrifugal | |||||||
| Driving method | Direct-drive | Belt-drive | |||||||
| Power | kw | 0.28×2 | 0.55×2 | 1.5 | 2.2 | 2.2 | 3 | ||
| Unit Dimension | L | mm | 1250 | 1250 | 1450 | 1650 | 1720 | 1800 | |
| W | mm | 600 | 600 | 800 | 800 | 800 | 800 | ||
| H | mm | 1600 | 1600 | 1700 | 1800 | 1950 | 1950 | ||
| Weight | kg | 140 | 160 | 225 | 280 | 320 | 350 | ||
| Outdoor unit | Compressor | Type | Hermetic Scroll | ||||||
| Power | kw | 3.75+2.25 | 3.75×2 | 4.5×2 | 3.75×3 | 4.5×3 | 3.75×4 | ||
| Unit Dimension | L | mm | 940 | 1050 | 1350 | 1350 | 1850 | 1950 | |
| W | mm | 940 | 1050 | 1050 | 1200 | 1050 | 1050 | ||
| H | mm | 1250 | 1300 | 1300 | 1300 | 1150 | 1150 | ||
| Weight | kg | 210 | 240 | 360 | 380 | 450 | 480 | ||
| Connecting tubes | Refrigerant gas tube | Size | Ф19.1+Ф15.9 | Ф19.1 | Ф19.1 | Ф19.1 | Ф19.1 | Ф19.1 | |
| Quantity | 1 | 2 | 2 | 3 | 3 | 4 | |||
| Refrigerant liquid tube | Size | Ф12.7+Ф9.52 | Ф12.7 | Ф12.7 | Ф12.7 | Ф12.7 | Ф12.7 | ||
| Quantity | 1 | 2 | 2 | 3 | 3 | 4 | |||
| Connection method | Outlet with flare | ||||||||
1. Cooling capacity is based on the following conditions: indoor air temperature DB27℃/WB19℃,ambient temperature,35℃ DB/24℃ WB.
2. Heating capacity is measured when indoor air temperature is 21 ℃,outside air temperature is DB7℃/WB6℃
3.* means the electric heating capacity of cooling and electric heating type units
4. The specifications are subject to change without notice for improvement.












Hot Tags: Ceiling ducted split air handling unit, China, manufacturers, customized, quotation, low price, made in China, 36HP Air Cooled Split Unit, 4 Ton Split Air Conditioner, Inverter Split Air Conditioner, 65kw Air Cooled Split Air Conditioner, 100kw Industrial Split Air Conditioner, Condenser Air Conditioning