Ground source heat pump 120KW
Ground source heat pump technology is a renewable energy utilization technology. Because the ground source heat pump is a heating and air conditioning system that uses shallow geothermal resources on the earth's surface (usually less than 400 meters deep) as a cold and heat source for energy conversion. The shallow geothermal resources on the surface can be called geothermal energy, which refers to the low-temperature thermal energy stored in the surface soil, groundwater or rivers and lakes by absorbing solar energy and geothermal energy. The shallow layer of the ground is a huge solar collector that collects 47% of the solar energy, which is more than 500 times the energy used by humans every year. It is not restricted by geography, resources, etc. It is truly large in quantity and ubiquitous. This kind of nearly unlimited renewable energy stored in the shallow layer of the earth makes ground energy a form of clean renewable energy.
| Model Type | Unit | HWWE90 | HWWE130 | HWWE180 | |||
| Cooling Condition | Cooling Capacity | KW | 88 | 132 | 176 | ||
| Power Input | KW | 16.9 | 25.3 | 33.8 | |||
| Evaporator (Application Side) | Cold Water Temp Inlet/Outlet | ℃ | 12/7 | ||||
| Cold Water Flow | m3/h | 15.1 | 22.7 | 30.2 | |||
| Cold Water Resistance | KPa | 38 | 42 | 43 | |||
| Condenser ( Water Source Side) | Cool Water Temp Inlet/Outlet | ℃ | 18/29 | ||||
| Cool Water Flow | m3/h | 8 | 12 | 16 | |||
| Cool Water Resistance | KPa | 18 | 20 | 21 | |||
| Heating Condition | Heating Capacity | KW | 98 | 147 | 196 | ||
| Power Input | KW | 22 | 33 | 44 | |||
| Evaporator (Water Source Side) | Cold Water Temp Inlet/Outlet | ℃ | 10/15 | ||||
| Cold Water Flow | m3/h | 8 | 12 | 16 | |||
| Cold Water Resistance | KPa | 18 | 20 | 21 | |||
| Condenser (Application Side ) | Hot Water Temp Inlet/Outlet | ℃ | 40/45 | ||||
| Hot Water Flow | m3/h | 15.1 | 22.7 | 30.2 | |||
| Hot Water Resistance | KPa | 38 | 42 | 43 | |||
| Refrigerant | R22/R134A/R407C | ||||||
| Compressor | Type | Flexible Hermetic Scroll /Screw Compressor | |||||
| Number | 4 | 6 | 4 | ||||
| Electric Performance | Voltage | 380V/3PH/50Hz or other power supply | |||||
| Security Protections | High and Low Pressure Protections, Overload Protection, Antifreeze and Water Short Protections | ||||||
| Chilled Water Pipe Connection | DN | 125 | 150 | 150 | |||
| Cooled Water Pipe Connection | DN | 50 | 50*2 | 50*2 | |||
| Dimensions | Length | mm | 2200 | 2000 | 2200 | ||
| Width | mm | 600 | 1000 | 1000 | |||
| Height | mm | 1500 | 1500 | 1500 | |||
| Noise Level | dB(A) | 56 | 58 | 60 | |||
| Weight | kg | 280 | 400 | 600 | |||











Hot Tags: geothermal heat pump water chiller, China, manufacturers, customized, quotation, low price, made in China, 25kw Water Cooled Heat Pump Chiller, Water Cooled Screw Chiller, Water Cooled Screw Compressor Chiller, 1000kw Industrial Water Cooled Chillers, 200ton Water Cooled Screw Chiller, HVAC Industrial Commercial Screw Chiller